Lucent Technologies 6.1 Manuel D’Utilisation

Page de 588
MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Control Unit Configuration 
Page 2-2
Planning Module Placement 
2
Planning Module Placement
2
In addition to the processor module and power supply module, the system 
supports several types of line/trunk and extension modules. Deciding how to 
place the modules in the carriers consists of the following tasks:
1.
Calculating the system’s line/trunk capacity according to module types
2.
Calculating the system’s extension capacity according to module types
3.
Mapping out module placement on the Control Unit Diagram, according to 
specific guidelines
This section contains instructions for each of these tasks.
For information about calculating unit load requirements, see Appendix F, “Unit 
Load Calculation”. 
For detailed information about modules and their specifications (including 
line/trunk and extension capacity), see the descriptions of hardware components 
contained in the 
Pocket Reference.
Forms Needed
2
Equipment List (if available)
Capacity for Lines/Trunks
2
Line/trunk capacity is the number of lines/trunks that can be connected to the 
control unit. This section contains instructions for calculating the systems capacity 
for lines/trunks, according to the system’s module types.
Planning Form Instructions
2
1.
In the table in the Line/Trunk Capacity section of Form 1, System Planning, 
fill in the number of each type of line/trunk module on the appropriate line of 
the Number of Modules column.
2.
Add the column and record the result at the bottom of the column on the 
System Totals line.
3.
For each module type noted, multiply the value in the Number of Modules 
column by the value in the Trunks Supported by Module column; write the 
results in the appropriate row under Total Trunks by Module Type.
4.
Add the column and record the total line/trunk capacity of the system at the 
bottom of the column, on the System Totals line.