Maytag DGRSC Manuel D’Utilisation
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and shut off gas to unit before
servicing, unless testing requires power.
servicing, unless testing requires power.
©2004 Maytag Services
16023219
13
Illustration Component
Test
Procedure
Results
Oven light housing
Disconnect connector and test
resistance of terminals......................
Measure voltage at oven light...........
resistance of terminals......................
Measure voltage at oven light...........
Verify bulb is plugged in properly.
Indicates continuity with bulb installed.
12 VAC, see wiring diagram for
terminal identification.
If no voltage is present at oven light,
check wiring or light switches.
Indicates continuity with bulb installed.
12 VAC, see wiring diagram for
terminal identification.
If no voltage is present at oven light,
check wiring or light switches.
Rocker switch
Measure continuity of switch positions:
Closed ..............................................
Open ................................................
Open ................................................
Continuity
Infinite
Convection motor fan
Verify supply voltage..........................
Check continuity of terminals, and
verify terminals are not shorted to
chassis...............................................
Check continuity of terminals, and
verify terminals are not shorted to
chassis...............................................
120 VAC
Approximately 80
Approximately 80
Ω
Controls
Verify proper operation.
Open at 225
°F, Closes at 165°F
Griddle thermostat
Verify supply voltage..........................
120 VAC
Oven thermostat
Verify supply voltage..........................
120 VAC
Pressure regulator
Verify gas pressure (WCP).
If on LP service, verify proper gas
supply conversion.
If on LP service, verify proper gas
supply conversion.
5
"
Natural
10
"
LP/Propane
GND
L or N
Input
Spark module
4 + 0
4 + 0
Test for voltage at terminals
L and N...........................................
Polarity and ground ........................
Polarity and ground ........................
120 VAC
Not subject to polarity
Holder orifice
Verify gas pressure (WCP).
Check orifice for debris.
Check orifice for debris.
5
"
Natural
10
"
LP/Propane
Clean as needed.
Spark ignition
electrode
electrode
Test for resistance of spark lead ..........
Test ignitor to chassis ..........................
Test ignitor to chassis ..........................
Continuity
No continuity from ignitor to chassis.
No continuity from ignitor to chassis.