Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and shut off gas to unit before
servicing, unless testing requires power.
servicing, unless testing requires power.
14 16023219
©2004 Maytag Services
Illustration Component
Test
Procedure
Results
270
° valve
Verify gas is supplied.
Orifice adjusted for
Natural or LP.
Adjust set screw for simmer control.
Orifice adjusted for
Natural or LP.
Adjust set screw for simmer control.
See conversion section.
Spark 270
° switch
Unplug switch harness at rear of
range. Test for continuity at wire
terminals.
range. Test for continuity at wire
terminals.
Switch in LITE position.......................
Switch in any other position ...............
Switch in any other position ...............
120 VAC
Continuity
Infinite
Continuity
Infinite
Top surface burner
Verify gas is supplied ..........................
Verify burner cap is positioned
correctly.
Verify burner cap is positioned
correctly.
Check for obstructions in burner ports.