Gaggenau AW 230 790 Manuel D’Utilisation

Page de 64
20
Securing the appliance
1
Press the safety caps with the arrow upwards 
onto the brackets until they engage. 
®
2
Screw on knurled nut and washer firmly. 
¯
Removing safety caps
If the safety caps have to be removed, use a flat 
screwdriver.
Connecting the pipes
Note: If an aluminum pipe is used, smooth the 
connection area beforehand.
Exhaust-air pipe Ø 150 mm (recommended size)
Attach exhaust-air pipe directly to the air-pipe 
connector and seal.
Exhaust-air pipe Ø 120 mm
1
Attach reducing connector directly to the air-pipe 
connector.
2
Attach exhaust air pipe to the reducing connector. 
3
Seal both joints appropriately.
Attaching flue duct
9
WARNING
Risk of injury
From sharp edges during installation. Always 
wear protective gloves while installing the 
appliance.
1
Separate the flue ducts. 
To do this, remove the adhesive tape.
2
Remove the protective foil from both flue ducts.
3
Push one flue duct into the other.
Notes
‒ To prevent scratches, lay paper over the edges 
of the lower flue duct to protect the surface.
‒ The slots of the inner flue duct point 
downwards.
4
Place flue ducts on the appliance.
5
Push the inner flue duct upwards and attach it to 
the angle brackets on the left and right. 
¨
6
Press the flue duct downwards until it engages. 
©
7
Screw the flue duct to the sides of the angle 
bracket using two screws. 
ª
Removing the appliance
1
Loosen the flue duct.
2
Disconnect the appliance from the power supply.
3
Loosen the exhaust air lines.
4
Loosen screws for fastening the appliance.
5
Remove the appliance.
)
*
[
$
%
&