89
SECTION 3 - SERVICING COMPONENTS
Figure 56
PS360EWB or PS360WB70 gas train with Midco burner
Figure 57
PS360EWB or PS360WB70 gas train with Wayne burner
Air  shutter
42810-0087
Burner  blower
and  motor  assy,
208/240V
27170-0287
Manual  shutoff
valve,  3/4”
23115-0010
3/4” union
23051-0004
Combination gas
control  valve,  3/4”
32569
PS360EWB  ONLY:
M520 modulating
valve,  3/4”
32570
PS360WB70  ONLY:
Solenoid valve, 3/4”
31500
Pilot
pressure
tap
30185
Air  shutter
36830
Burner  blower
motor,
208/240V
32195
Manual  shutoff
valve,  3/4”
23115-0010
3/4” union
23051-0004
Combination gas
control  valve,  3/4”
32569
PS360EWB  ONLY:
M420 modulating
valve,  3/4”
32570
PS360WB70  ONLY:
Solenoid valve, 3/4”
31500
Pilot orifice
See chart on
Page 69
Pilot
pressure
tap
Pilot line
(1/4” aluminum tubing)
15125-0002
(per  foot)
PS360WB70
ONLY:
Bypass  line
(1/4” aluminum
tubing)
15125-0002
(per  foot)
Air  tube
(silicone  rubber)
22450-0297
(per  foot)
TO  NEGATIVE  (-)
SIDE OF AIR
SWITCH
Air  tube
(silicone  rubber)
22450-0297
(per  foot)
TO  POSITIVE  (+)
SIDE OF AIR
SWITCH
PS360WB70  ONLY:
Bypass  line
(1/4” aluminum tubing)
15125-0002
(per  foot)
Pilot line
(1/4” aluminum
tubing)
15125-0002
(per  foot)
Main orifice
See chart on
Page 69