Middleby Marshall PS224 PS310 Manuel D’Utilisation

Page de 181
91
PS360WB70/EWB PS360WB70/EWB
PS200
PS220/224
PS310/314/360
PS360WB
Midco burner
Wayne burner
PS555
PS570S/PS570G
Description
42810-0125 42810-0126 42810-0120 42810-0127
36863
44664
43061
42810-0127 GAS CONVERSION KIT,
PROPANE TO NATURAL
22176-0010 22176-0016 22176-0004 22176-0014
31821
22176-0014
43059
22176-0014 MAIN ORIFICE, NATURAL
0.204”/5.18mm
0.182”/4.62mm
0.219”/5.56mm
0.250”/6.35mm
0.234”/5.94mm
0.250”/6.35mm
0.228”/5.79mm
0.250”/6.35mm
GAS
22174-0011
22174-0011
22174-0011
22174-0011
31818
22174-0011
22174-0011
22174-0011 PILOT  ORIFICE,  NATU-
0.028”/0.71mm
0.028”/0.71mm
0.028”/0.71mm
0.028”/0.71mm
0.032”/0.81mm
0.028”/0.71mm
0.028”/0.71mm
0.028”/0.71mm
RAL GAS
22174-0006* 22174-0006* 22174-0006 22174-0006 22174-0006* 22174-0006*
NONE*
22174-0006* BYPASS ORIFICE, NATU-
0.060”/1.52mm/
0.060”/1.52mm/
0.060”/1.52mm/
0.060”/1.52mm/
0.060”/1.52mm/
0.060”/1.52mm/
0.060”/1.52mm/
RAL GAS
#53 drill
#53 drill
#53 drill
#53 drill
#53 drill
#53 drill
#53 drill
28092-0019 28092-0019 28092-0019 28092-0019 28092-0019 28092-0019 28092-0019 28092-0019 GAS VALVE SPRING KIT,
NATURAL GAS
42810-0122 42810-0123 42810-0119 42810-0124
36856
44665
43062
42810-0124 GAS CONVERSION KIT,
NATURAL TO PROPANE
22176-0007 22176-0017 22176-0003 22176-0015
31822
31980
43060
22176-0015 MAIN ORIFICE, PROPANE
0.1285”/3.26mm
0.113”/2.87mm
0.134”/3.40mm
0.152”/3.86mm
0.185”/4.70mm
0.165”/4.19mm
0.141”/3.58mm
0.152”/3.86mm
22174-0010 22174-0010 22174-0010 22174-0010
31819
22174-0010 22174-0010 22174-0010 PILOT ORIFICE, PROPANE
0.018”/0.45mm
0.018”/0.45mm
0.018”/0.45mm
0.018”/0.45mm
0.025”/0.64mm
0.018”/0.45mm
0.018”/0.45mm
0.018”/0.45mm
22174-0009* 22174-0009* 22174-0009 22174-0009 22174-0009* 22174-0009*
NONE*
22174-0009* BYPASS ORIFICE, PRO-
0.038”/0.97mm/
0.038”/0.97mm/
0.038”/0.97mm/
0.038”/0.97mm/
0.038”/0.97mm/
0.038”/0.97mm/
0.038”/0.97mm/
PANE
#62 drill
#62 drill
#62 drill
#62 drill
#62 drill
#62 drill
#62 drill
28092-0018 28092-0018 28092-0018 28092-0018 28092-0019 28092-0018 28092-0018 28092-0018 GAS VALVE SPRING KIT,
(same  as
PROPANE
natural  gas)
*
NOTE
Bypass orifices are used ONLY  on  ovens  equipped  with  an  on-off  gas  regulation  system  (with  a  solenoid  valve).   These  ovens  include:
B. Part Number Reference - Gas Orifices and Gas Conversion Kits
Figure 60 - Wayne burner - exploded view
Pilot/ignitor
assembly
42810-0117
Pilot shield
27170-0204
Venturi
Wtih angled flame target:
27170-0223
With round flame target:
38127
Pilot orifice
See  chart  below
Main orifice
See  chart  below
Pitot tube assembly
(for  use  with  208/
240V  motors)
42400-0640
Air  shutter
42810-0087
Burner  blower  and  motor  assy
120V:    27170-0011
208/240V:    27170-0287
•
PS200-series
(through  3/02)
•
PS310
•
PS314
Ovens equipped with a PID modulated gas system (with a modulating valve) do not use a bypass orifice.  These ovens include:
•
PS200-series
(4/02  or  later)
SECTION 3 - SERVICING COMPONENTS
NOTE:  Installations at higher altitudes have a lower ambient air pressure that disrupts the air-fuel mixture.  To correct this
problem, smaller gas orifices are required.  A general rule is a 4% reduction for each 1000 ft. (305m) above sea level.  Refer
to the chart in the Appendices section (page 135) for a listing of orifice sizes showing this reduction.
•
PS360
•
PS360WB
•
PS360WB70
•
PS570S (through 8/00)
•
PS360EWB
•
PS555
•
PS570S
(9/00  or  later)
•
PS570G