Jenn-Air JGS9900BD Manuel D’Utilisation

Page de 73
Troubleshooting Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury, or death, disconnect power and gas to range before servicing, 
unless testing requires power and/or gas. 
14 16026923 
© 2006 Maytag Services
 
Oven Sensor, Meat Probe and Cooling Fan Temperature Charts 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
OVEN SENSOR 
Sensor Type:
 RTD 
1000 
Ω platinum 
Calibration:
 1654 
Ω (350° F / 177° C) 
Temperature F (C) 
Resistance (Ohms) 
100 (38) 
1143 
200 (94) 
1350 
300 (149) 
1553 
350 (177) 
1654 
400 (204) 
1753 
500 (260) 
1949 
600 (316) 
2142 
700 (371) 
2331 
800 (427) 
2516 
900 (483) 
2697 
1000 (538) 
2874 
MEAT PROBE 
Type:
 NTC 
Thermistor 
Calibration:
 9938 
Ω (150° F / 65.5° C) 
Temperature F (C) 
Resistance (Ohms) 
32 (0) 
163300 
68 (20) 
62450 
95 (35) 
32660 
122 (50) 
18020 
158 (70) 
8760 
185 (85) 
5360 
212 (100) 
3400 
COOLING FAN TEMPERATURES 
MODE 
FAN ON TEMP F (C) 
FAN OFF TEMP F (C) 
Bake 
350 (177) 
300 (149) 
Broil 
Six (6) minute delay 
after cycle started 
225 (107) 
Clean 
Six (6) minute delay 
after cycle started 
225 (107)