Component Testing Procedures 
Illustration Component 
Test 
Procedure 
Results 
 
 
Oven light & housing 
Disconnect connector  and test 
resistance of terminals .............................
Measure voltage at oven light...................
Verify bulb is properly inserted. 
Continuity with bulb inserted. 
120 VAC, see wiring diagram for terminal 
identification. 
If voltage is not present at oven light, 
check wiring or light switches. 
 
 
Door plunger switch 
Remove switch from unit and measure 
the following points: 
Door closed...........................................
Door open .............................................
 
 
COM-NO:
.....Continuity (closed). 
COM-NO:
.....Infinity (open). 
 
 
Autolatch assembly 
Disconnect wires and test for continuity 
per wiring diagram....................................
Refer to Parts Manual for correct 
autolatch switch associated with the 
correct manufacturing number. 
 
See wiring diagram for schematic layout. 
Common is in neutral position unless 
locking or unlocking autolatch assembly. 
 
COM NO
 
Door lock switch 
Switch connection in the following 
positions: 
Door latch locked......................................
Door latch unlocked..................................
 
 
COM-NO:
.....Continuity (closed). 
COM-NO:
.....Infinity (open). 
 
 
Pressure regulator 
Verify gas pressure (W.C.P.)....................
 
If on LP service verify proper gas supply 
conversion. 
5" Natural. 
10" LP/propane. 
Gas ON:
.......Switch up. 
Gas OFF:
.....Switch down. 
 
 
Oven valve 
Verify gas supply is turned on at 
regulator ...................................................
Attached to pressure regulator. 
 
Gas ON:
.......Switch up (at regulator). 
Gas OFF:
.....Switch down (at regulator). 
 
 
Broil burner 
Verify gas is supplied. 
Orifice adjusted for Natural or LP .............
Check for obstructions or contamination 
in ports .....................................................
Factory set to Natural Gas.
 
Adjust as necessary. 
Air shutter opening set to .281 to .343. 
Replace if punctured or torn. 
JGS9900BD* 
 
Bake burner 
Verify gas is supplied. 
Orifice adjusted for Natural or LP .............
Check for obstructions or contamination 
in ports .....................................................
Factory set to Natural Gas.
 
Adjust as necessary. 
Air shutter opening set to .281 to .343. 
Replace if punctured or torn. 
 
 
Bake burner 
Verify gas is supplied. 
Orifice adjusted for Natural or LP .............
Check for obstructions or contamination 
in ports .....................................................
Factory set to Natural Gas.
 
Adjust as necessary. 
Air shutter opening set to .469 to .531. 
Replace if punctured or torn. 
 
 
Ignitor 
Test for voltage at terminals .....................
Test for circuit amperage..........................
(Ignitor may glow but not have sufficient 
amperage to open valve.) 
120 VAC. 
3.2 - 3.6 Amps. If not, replace. 
 
 
Hi-limit temperature 
switch 
Normally closed, verify operation: 
Open:
 249° to 271° F (121° to 133° C) ...
Closed
: 173° to 207° F (78° to 97° C) ....
 
Infinite. 
Continuity. 
 
L
A
B
A1
B1
N
 
Spark module 4 + 0 
Test for voltage at terminals L and N........
 
Check polarity and ground........................
120 VAC. 
 
See wiring diagram. 
 
 
Temperature sensor 
 
Measure resistance.................................. Approximately 1000 Ω at room 
temperature 75° F (23.8° C). 
 
 
Cooling fan motor 
Measure voltage.......................................
Check motor windings to ground ..............
120 VAC. 
No continuity. 
RPM: