Metrologic Instruments IS3480 Manuel D’Utilisation

Page de 56
 
 
9
I
NSTALLATION
 
 
Stand-Alone Keyboard 
 
1.  Turn off the host device. 
2.  Plug the male 10-pin RJ45 end  
of the PowerLink cable into the  
10-pin socket on the IS3480. 
3.  Connect the other end of the 
PowerLink cable to the keyboard 
port on the host device. 
4.  Plug the external power supply into 
the power jack on the PowerLink 
cable. 
Check the AC input 
requirements of the power 
supply to make sure the 
voltage matches the AC 
outlet.  The outlet must be 
located near the equipment 
and be easily accessible. 
 
5.  Connect AC power to the 
transformer. 
6.  Turn on the host device. 
 
When the scanner first receives power, the blue LED will turn on; the 
scanner will simultaneously beep once and flash the white LED. 
 
Powering the IS3480 directly from the host device can sometimes 
cause interference with the operation of the scanner or the computer.  
Not all computers supply the same current through the keyboard port.  
For this reason, Metrologic recommends using an external power 
supply.  For additional information contact a Metrologic customer 
service representative. 
 
Caution:  
 
To maintain compliance with applicable standards, all circuits connected to the scanner 
must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 
60950.  
 
To maintain compliance with standard CSA C22.2 No. 60950/UL 60950 and norm 
EN/IEC 60950, the power source should meet applicable performance requirements for 
a limited power source. 
 
Figure 7.