Cable Installation and Removal  
Installation 
Important:  If the cable is not fully latched, the unit can power intermittently. 
 
 
Figure 2.  Connecting the Cable 
 
1.  Plug the 10-pin RJ45 end of the cable into the 10-pin socket on the scanner.  
There will be an audible click when the connector lock engages. 
2.  Gently pull on the cable strain relief to insure the cable is securely installed. 
 
Removal 
 
Before removing the cable from the scanner, Metrologic recommends that power 
to the host system be turned off.  If the cable is a PowerLink cable, disconnect 
the power supply on the cable.  
 
 
Figure 3.  Releasing the Cable 
 
1.  Locate the small dimple on the handle of the unit near the cable connection. 
2.  Bend an ordinary paperclip into the shape shown above in Figure 3
3.  To release the cable lock, push the end of the paperclip through the rubber 
on the handle where the dimple is located.  
4.  There will be an audible click when the connector lock releases.  Pull gently 
on the strain-relief of the cable to separate the cable from the scanner.