Chapter 4 Regulatory Specifications and Declarations
4.3
Essential Compliance Information
This section documents miscellaneous points that should be observed to ensure the proper and safe use of 
this product worldwide. 
4.3.1
Safety
Users of these products must refer to the safety information included in 
Service personnel must also refer to the safety information in 
It is not intended for these products to be installed in a home or residential environment. It is not intended 
for these products to be installed or operated in a stressful or inordinary environment such as industrial 
sites, medical applications, or in flammable/explosive environments. These products are designed for 
installation in buildings with a power distribution that contains a protective earth conductor. 
4.3.2
EMC
Warning: This is a class A product. In a domestic environment this product may cause radio 
interference in which case the user may be required to take adequate measures.
4.3.2.1
Installation of Cables
In order to ensure that the EMC performance of the products meet regulatory requirements: 
Cables used for the PCM interface ports (T1/E1) shall be twisted-pair screened cables, grounded at both 
ends. 
Cables used for the Ethernet interfaces shall be shielded cables, grounded at both ends. 
Cables used for the SS7 serial interface ports (V.11), marked AUX, shall be shielded cables, grounded at 
both ends, and have the ferrite clamps, provided with the product, installed close to the connector 
backshell. 
Cables used to connect a DC powered product to a DC source, and the safety ground conductor, when 
installed in locations other than telecommunications centres, shall be less than 3 metres long. 
4.3.2.2
Further Information
For further information on good EMC practice, the installer should consult the IEC61000-5-x series of 
technical reports on the subject of “Electromagnetic Compatibility (EMC) - Installation and Mitigation 
Guidelines”. In particular, the following sections are recommended: 
IEC61000-5-1 - General Considerations 
IEC61000-5-2 - Earthing and Cabling 
IEC61000-5-6 - Mitigation of External EM Influences 
4.3.3
Telecommunications
The telecommunication interfaces of these products are not intended for direct connection to “outside plant” 
signal conductors (metallic). These products shall be isolated, by channel banks or office repeaters, from any 
connections to network or terminal equipment, that lie outside of the same building. The telecommunication 
interface connections are considered to be, and meet the requirements of, SELV circuits (not TNV). Refer 
also to any region specific information on network connection (see 
 an
).