Metrologic Instruments MS7320 Manuel D’Utilisation

Page de 64
 
 
I
NSTALLATION FOR 
RS232
 OR 
L
IGHT 
P
EN 
I
NTERFACES
  
 
1.  Turn off the host system. 
 
2.  Connect the PowerLink cable to the 
10-pin RS232/Light Pen interface 
jack.  It is the 1
st
 round opening from 
the left side of the MS7320
 
 
(see figure 5).
 
 
3.  Connect the other end of the 
PowerLink cable to the host. 
 
Before continuing verify that the 
PowerLink cable is connected to the 
appropriate interface jack on the 
scanner.  An incorrect cable connection 
can cause communication problems or 
potential damage to the scanner.  
 
4.  Connect the external power supply to 
the power jack on the PowerLink 
Cable. 
 
5.  Check the AC input requirements of 
the power supply to make sure the 
voltage matches the AC outlet.  
 
6.  Connect AC power to the 
transformer.  The outlet should be 
near the equipment and easily 
accessible. 
 
7.  Scan the appropriate bar codes on 
page 9 to configure the MS7320 for 
RS232 or Light Pen communication. 
 
8.  Turn on the host system. 
 
9.  Snap on the cable cover. 
 
 
 
 
 
 
See SELV Power Source caution statement located on page 16 of this manual. 
 
 
Figure 5:  RS232 or  
Light Pen Interface