7
I
NSTALLATION FOR 
USB
 
I
NTERFACE 
 
 
1.  Turn off the host system. 
 
2.  Determine if your application requires USB 
Keyboard
 communication protocols or 
USB Point-of-Sale
 communication 
protocols. 
 
3.  If you require USB Keyboard 
communication protocols, skip to step 4. 
 
If you require USB Point-of-Sale 
communication protocols set the dip 
switches shown in figure 4a to positions  
1 and 2.  
 
4.  Connect the PowerLink cable to the 10-pin 
USB interface jack.  It is the 2
nd
 round 
opening from the left side of the MS7320
 
(see figure 4b)
.  
 
5.  Connect the other end of the USB cable to 
the host. 
 
Before continuing verify that the USB 
cable is connected to the appropriate 
interface jack on the scanner.  An incorrect 
cable connection can cause 
communication problems or potential 
damage to the scanner.  
 
Plugging the scanner into the USB 
port of the PC does not guarantee 
that scanned information will appear 
at the PC.  A software driver and 
correct configuration setting are also 
required for proper communication. 
 
6. Scan  the Enable USB Defaults bar code to 
configure the MS7320 for USB 
communication. 
 
7.  Turn on the host system.  
 
8.  Snap on the cable cover. 
 
 
 
 
 
See SELV Power Source caution statement located on page 16 of this manual. 
 
Figure 4a: POS Dip Switch
Figure 4b: USB, Interface
³ 9 9 9 9 7 8
Enable USB Defaults