Q-Logic 16HA Manuel D’Utilisation

Page de 122
Preliminar
y
Cascade Topology 
SANbox-16HA Fibre Channel Switch
Installer’s/User’s Manual
59005-03 Rev. A
 Multi-Chassis Fabrics   
5-5
Cascade Topology
The term “cascade” indicates that chassis are connected in a line “one-to-the-
next”. You may optionally have chassis interconnections from the last chassis back 
to the first chassis (Loop). The loop provides better latency because any chassis can 
route traffic in the shortest direction to any another chassis in the loop. The loop 
also provides failover when only one chassis interconnection is used. 
 
shows an example of Cascade-with-a-loop interconnection.
Figure 5-1   Cascade Example
In fabrics containing two or three chassis, Cascade-with-a-loop topology and Mesh 
topology are exactly the same. Note in 
 that if the fabric contained only 
three chassis and the loop back to the first chassis came from chassis 3, that each 
chassis would be directly connected to each other chassis which is the definition of 
Mesh topology.
1
2
3
4
5
6
7
8