Q-Logic 16HA Manuel D’Utilisation

Page de 122
Preliminar
y
Multistage Topology 
SANbox-16HA Fibre Channel Switch
5-12
  Multi-Chassis Fabrics 
59005-03 Rev. A
Installer’s/User’s Manual
Multistage Topology
A Multistage Switch consists of chassis configured in two different Stage Types, an 
Input-Output/Transfer (IO/T) stage type, and a Cross-Connect (CC) Stage Type. 
Two or more chassis with the IO/T Stage Type supply user ports to connect to the 
users, and T_Ports that connect to one or more chassis with the CC Stage Type. The 
chassis with the CC Stage Type supply interconnections for the T_Ports. Any 
SANbox chassis can function as an IO/T Stage Type or as a CC Stage Type. Switch 
management allows you to designate the Stage Type of any chassis as IO/T or CC. 
The default Stage Type for any chassis is IO/T.
T_Port Rules for SANbox IO/T Chassis
Any port on a SANbox-8 or 16 IO/T chassis may be a T_Port. T_Ports are used to 
interconnect chassis and are not user ports. QLogic suggests that you not use more 
than half of the ports on a chassis as T_Ports. Chassis numbers must be unique 
among all IO/T chassis in a fabric. If there is a chassis number conflict, the switch 
with the higher world wide name will be disabled. In addition, a Logged-In LED 
on the switch with the lower world wide name will blink to indicate which port is 
connected to the conflicting switch.
You must connect at least one T_Port on each IO/T chassis to each CC chassis.
T_Port Rules for SANbox Cross-Connect (CC) Chassis
All ports on a SANbox CC chassis are T_Ports. As T_Ports they are used to inter-
connect chassis and are not user ports. Chassis numbers must be unique among all 
CC chassis in a fabric. If there is a chassis number conflict, the switch with the 
higher world wide name will be disabled. In addition, a Logged-In LED on the 
switch with the lower world wide name will blink to indicate which port is 
connected to the conflicting switch. Each CC chassis must have at least one T_Port 
connection from each IO/T chassis.
Multistage Fabric Size
SANbox-16 chassis connected in Multistage topology (All SANbox-16 chassis) 
expand from three chassis to a maximum of 17 to 24 chassis (16 IO/T chassis and 
one to eight CC chassis). This results in 128 to 240 user ports depending on the 
number of T_Ports used to interconnect the chassis.
Multistage Latency
Latency between any two user ports on different chassis is three chassis hops 
(counting the source and destination chassis).