5 – Diagnostics/Troubleshooting
POST Diagnostics
5-8
59042-06 A
0
4.
Display the active zone set on each switch using the Zoning Active 
command or the Active Zoneset tab of the SANsurfer Switch Manager 
topology display. Compare the zone membership between the two active 
zone sets. Are they the same?
„
Yes - Contact your authorized maintenance provider.
„
No - Deactivate one of the active zone sets or edit the conflicting zones 
so that their membership is the same. Reset the port. If the condition 
remains, contact your authorized maintenance provider.
5.1.2.2
Excessive Port Errors
The switch monitors a set of port errors and generates alarms based on 
user-defined sample windows and thresholds. These port errors include the 
following:
„
CRC errors
„
Decode errors
„
ISL connection count
„
Login errors
„
Logout errors
„
Loss-of-signal errors
Port threshold alarm monitoring is disabled by default. Refer to the 
SANbox2-8c/16 Switch Management User’s Guide for information about 
managing port threshold alarms.
If the count for any of these errors exceeds the rising trigger for three consecutive 
sample windows, the switch generates an alarm and disables the affected port, 
changing its operational state to “down”. Port errors can be caused by the 
following:
„
Triggers are too low or the sample window is too small
„
Faulty Fibre Channel port cable
„
Faulty SFP
„
Faulty port
„
Fault device or HBA
Note:
This can be caused by merging two fabrics whose active 
zone sets have two zones with the same name, but 
different membership.