GigWorks MKII-16 Switch Model MKII-BASE16
Installer's/User's Manual            59003-01 Rev. A
Removal/Replacement Procedures  
5-5
GBIC
Replacement
GBICs may be removed and replaced with the power on and the Switch operating
without disrupting traffic on other ports.
1.
Orient the GBIC as shown in the drawing below. The Keyway is ON THE
BOTTOM (as shown) for the top row of ports and ON THE TOP  for the
bottom row of ports.
2.
Slide the GBIC into the port opening (the spring-loaded door will open as
you push the GBIC in). If you can only slide the GBIC in about an inch (2.5
cm) before it stops, you have the Keyway in the wrong position; flip the
GBIC over and try it again.
3.
Push the GBIC in until the GBIC Latches snap into place. If you have a
GBIC that has bail-operated latches, make sure that the bail is rotated down.
This allows the latches to latch (refer to the Removal procedure for a
picture).
4.
Cable the port. Refer to the Installation section of this manual for cabling
instructions.
GBIC Latches (one on each side)
GBIC
GBIC 
Connector
Port Connector
Keyway