59263-01  A
S
Notes
 describes the port test parameters.
To cancel a port test that is in progress, enter the 
 Port command.
To display the status of the most recent port test or port test in progress, enter the 
 Port command.
Examples
The following example performs an online test on port 1:
SANbox #> admin start
SANbox (admin) #> test port 1 online
A list of attributes with formatting and current values will follow. Enter a new 
value or simply press the ENTER key to accept the default value. If you wish to 
terminate this process before reaching the end of the list press 'q' or 'Q' and the 
ENTER key to do so.
LoopCount     (decimal value, 1-4294967295)   [429496729]
FrameSize     (decimal value, 40-2148)        [256      ]
DataPattern   (32-bit hex value or 'Default') [Default  ]
StopOnError   (True / False)                  [True     ]
LoopForever   (True / False)                  [False    ]
Do you want to start the test? (y/n) [n] y
The test has been started.
A notification with the test result(s) will appear
on the screen when the test has completed.
SANbox (admin) #>
  Test for port 1 Passed.
Table 14-44. Port Test Parameters
Parameter
Description
LoopCount
Number of frames sent
FrameSize
Number of bytes in each test frame
DataPattern
Pattern in the payload
StopOnError
Stops the test when an error occurs (True). 
Otherwise, the test continues to comple-
tion.
LoopForever
Restarts the test after completion and con-
tinues until you cancel it (True). Otherwise, 
the test ends normally after completion.