APC G50B-20A2 Manuel D’Utilisation
5
APC A/V G-Type Rack Power Filter: Operation
Operation
Basic Functions
Note: The LCD display interface screen and LEDs can be dimmed, using the Setup menu.
Press any button on the front panel of the unit to illuminate the display screen and the LEDs.
Press any button on the front panel of the unit to illuminate the display screen and the LEDs.
Front panel buttons
Use the display interface on the front of the G50B-20A2 to configure and operate the unit.
Power.
Push to apply power to the unit or to shut off power to the unit.
Status.
Push to display the current status of the unit, including the current input/output voltage.
Setup.
Push to scroll through the setup menus.
Up/Down.
Push to change values (Setup menu) and browse menu pages (Status menu).
Display interface LEDs
There are eleven LEDs on the display interface.
LED
Illuminated
Not Illuminated
P
OWER
ON
The unit is supplied with utility
power.
power.
There is no input utility power.
L
INE
OK
The utility power is within
acceptable range, 92 V to 140 V.
acceptable range, 92 V to 140 V.
The input voltage from utility power is outside the
acceptable range and the unit has disconnected from
utility power to protect the connected equipment.
acceptable range and the unit has disconnected from
utility power to protect the connected equipment.
P
ROTECTION
W
ORKING
The unit is protecting all connected
equipment.
equipment.
The unit is not providing power protection. See
Troubleshooting and contact APC Technical Support
immediately.
Troubleshooting and contact APC Technical Support
immediately.
W
IRING
OK
The unit is functioning properly.
There is a problem with the building wiring. Contact a
certified electrician.
certified electrician.
O
VERLOAD
The unit is overloaded. Disconnect
some connected components.
Contact APC Technical Support.
some connected components.
Contact APC Technical Support.
The unit is functioning properly.
D
ELAY
1
Power is being supplied to
D
ELAY
1
. Power is not being supplied to
D
ELAY
1
.
D
ELAY
2A
Power is being supplied to
D
ELAY
2A
.
Power is not being supplied to
D
ELAY
2A
.
D
ELAY
2B
Power is being supplied to
D
ELAY
2B
.
Power is not being supplied to
D
ELAY
2B
.
D
ELAY
3
Power is being supplied to
D
ELAY
3
. Power is not being supplied to
D
ELAY
3.
D
ELAY
4
Power is being supplied to
D
ELAY
4
. Power is not being supplied to
D
ELAY
4
.
S
WITCHED
Power is being supplied to the
S
WITCHED
outlet.
Power is not being supplied to the
S
WITCHED
outlet.
Utility Source
122V 60Hz