5-25 
Station Ageing 
 
 
 
 
         AGEING  ( Device name - FCD-IPM ) 
         ------ 
 
   Enter ageing time for stations learned by Remote 
   Access Server. 
 
 
   ESC - Return to previous menu 
   Current station ageing     (minutes): 60 
   New stations ageing (1- 255 minutes): 
Figure 5-29.  Station Aging Menu 
Station aging determines the amount of time a station is allowed to be inactive 
before it is removed from the network. A station is inactive when no traffic from it 
is received by the FCD-IPM LAN interface. This parameter is used in IP routing 
mode for ARP table aging and in bridge mode for MAC station table aging. Static 
stations are not removed by the aging mechanism. 
The default aging time is 60 minutes