RAD Data comm Modular Access Device with Integrated Router Manuel D’Utilisation

Page de 224
Chapter 5  Setup Menu 
FCD-IPM Installation and Operation Manual 
5-90 
WAN Economy Menu
 
 
To exit filtering and return to the main Setup menu, press <Esc>. The following 
prompt appears: 'up' (Y/N)? 
Press Y to save changes in the Flash Memory. Press N to cancel your changes. The 
system loads the previous set of masks the next time the system is rebooted. 
Connection on Demand 
 
 
 
 
Connection On Demand (Device name - FCD-IPM) 
-------------------- 
 
 1. Start Connection 
 2. Terminate Connection 
 3. Minimum Time Between Two Connects 
 4. Minimum Time Between Two Disconnects 
 5. Connect Manually 
 6. Disconnect Manually 
 
 
 
 ESC - Return to previous menu 
 Choose one of the above: 
Figure 5-91.  Connection On Demand Menu 
To save money, you may want to limit the time that a link is kept open. COD 
allows you to determine the traffic conditions that open and close the link. Using 
COD, a line is opened only when traffic conditions fulfill specified conditions. 
When there is no need for a connection, the line is automatically terminated. 
COD is only effective if: 
•  The line is connected to a modem or ISDN (a dialup link) 
•  The link is asynchronous 
•  The connection type is Originate or Answer&Originate.  
If the connection type is Answer only, the line connection is started when the unit 
is turned on in order to receive calls. If the connection type is Originate only or 
Answer&Originate the connection starts when a telephone number is defined. 
Advanced Menu 
Setup Menu 
WAN Economy Menu 
Connection on Demand