Site Requirements & Prerequisites 
2-1 
Chapter 2 
Installation and Setup 
This chapter provides instructions for mechanical and electrical installation of the 
FCD-IPM unit.  
After installation, you must configure the unit before further operation. Refer to 
Chapter 4
 for basic and advanced configuration instructions. In case a problem is 
encountered, refer to 
Chapter 5
 for test and diagnostics instructions. 
 
 
No internal settings, adjustment, maintenance, and repairs may be performed 
by either the operator or the user; such activities may be performed only by a 
skilled technician who is aware of the hazards involved. Always observe 
standard safety precautions during installation, operation, and maintenance of 
this product.  
 
2.1  Site Requirements & Prerequisites 
Install AC powered FCD-IPM units within 1.5m (5 feet) of an easily accessible, 
grounded AC outlet capable of furnishing the nominal supply voltage, 115 or 
230 VAC. DC powered units require a 24 or -48 VDC power source. 
Allow at least 90 cm (36 inches) of frontal clearance for operator access. Allow at 
least 10 cm (4 inches) clearance at the rear for interface cable connections. The 
ambient operating temperature of FCD-IPM is 0° to 50°C (32° to 122°F), at a 
relative humidity of up to 90%, non-condensing. 
 
The FCD-IP units are cooled by free air convection therefore in rack installation it is 
necessary to leave sufficient space (at least 1U) above and below each unit to 
enable free airflow. 
 
 