Chapter 2  Installation and Setup 
 
Interfaces and Connections 
2-5 
Control Port Connection 
The FCD-IPM control port is located on the front panel. Connect the ASCII 
terminal to this port. For more information on connecting to the control port, refer 
to 
Connecting to the ASCII Terminal
 in 
Chapter 3
Connecting the Power 
For your protection, FCD-IPM must always be grounded. Any interruption of the 
protective (grounding) conductor (inside or outside the instrument) or 
disconnecting the protective earth terminal can make this instrument dangerous. 
Intentional interruption is prohibited. 
 
BEFORE POWERING UP AN AC POWERED FCD-IPM, the protective earth 
terminals of this instrument must be connected to the protective conductor of 
the (mains) power cord. The mains plug shall only be inserted in a socket 
outlet provided with a protective ground (earth) contact. The protective action 
must not be negated by use of an extension cord (power cable) without a 
protective conductor (grounding). 
Make sure that only fuses with the required rated current and of the specified 
type, as marked on the FCD-IPM rear panel, are used for replacement. Use of 
repaired fuses and short-circuiting of fuse holders is forbidden. 
Whenever it is likely that the protection offered by fuses has been impaired, 
the instrument must be made inoperative and be secured against any 
unintended operation. 
 
AC Power Connection 
AC power should be supplied to FCD-IPM through the 1.5m (5 feet) standard 
power cable terminated by a standard 3-prong plug. 
 
To connect the AC power: 
1.  Check that the ON/OFF switch on the FCD-IPM rear panel is set to OFF. 
2.  Connect the power cable to the connector on the FCD-IPM rear panel. 
3.  Connect the power cable to the mains outlet. 
DC Power Connection 
 
To connect the DC power: 
1.  Check that the ON/OFF switch on the FCD-IPM rear panel is set to OFF. 
2.  Connect the power cable to the DC power connector. 
Constraints 
 
Do not hot swap the FCD-IPM modular IO data channel cards. A card must be 
added to or removed from an IO slot when the power is off ONLY. 
 
 
Warning 
Warning