RAD Data comm Modular Access Device with Integrated Router Manuel D’Utilisation

Page de 224
Chapter 3  Operation 
FCD-IPM Installation and Operation Manual 
3-2 Indicators
 
 
Table 3-1.  Front Panel Indicator Functions 
Object Description 
Function 
POWER 
Green LED 
ON when FCD-IPM is powered on. 
READY/LOOP  Green LED 
ON when packets can be transferred. 
Blinks – a loopback is active on E1, T1 or SHDSL link 
LAN 1 DATA 
LAN 2 DATA 
Yellow LED 
ON when a packet is received or transmitted on the 
LAN side. 
LAN 1 ERR 
LAN 2 ERR 
Red LED 
ON when a LAN interface indicates an error. 
LINK 1 DATA 
LINK 2 DATA 
Yellow LED 
Turns ON briefly when a packet is received or 
transmitted on the LINK side. 
LINK1 ERR 
LINK2 ERR 
Red LED 
OFF when there is a physical connection and no LINK 
interface error. 
Turns ON briefly when LINK interface indicates an 
error. 
Continuously ON when there is no physical connection. 
LINK1 RED 
ALARM  
Red LED 
ON when T1 link is in RED ALARM.  
Local unit lost frame synchronization for more than 
2.5 consecutive seconds. 
SUB RED 
ALARM  
Red LED 
ON when one of the T1 sub link is in RED ALARM.  
Sub link of the local unit lost frame synchronization for 
more than 2.5 consecutive seconds. 
LINK1 
YELLOW 
ALARM  
Yellow LED 
ON when one of the T1 sub link is in YELLOW ALARM. 
Yellow alarm signal is sent from Remote Unit to inform 
the local unit that a RED ALARM exists at the remote 
end.  
SUB YELLOW 
ALARM  
Yellow LED 
ON when one of the T1 sub  link is in YELLOW ALARM. 
Yellow alarm signal is sent from Remote Unit to inform 
the sub link of the local unit that a RED ALARM exists at 
the remote end.  
LINK1 LOC  
SYNC LOSS 
Red LED 
ON when E1 link is in local sync loss alarm. 
Local unit lost frame synchronization for more than 2.5 
consecutive seconds. 
SUB LOC 
SYNC LOSS 
Red LED 
ON when one of the E1 sub link is in local sync loss 
alarm. 
Sub link of  the local unit lost frame synchronization for 
more than 2.5 consecutive seconds.