Huawei MC509 Manuel D’Utilisation

Page de 156
 
HUAWEI MC509 CDMA LGA Module 
AT Command Interface Specification 
Audio Commands 
 
Issue 01 (2011-08-26) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
126 
 
Command 
Possible response(s) 
+CLVL=? 
<CR><LF>+CLVL: (list of supported <level>s) 
<CR><LF><CR><LF>OK<CR><LF> 
<CR><LF>+CME ERROR: <err><CR><LF> 
 
11.4.2 Description 
This command is used to select the volume of the internal loudspeaker of the MT.   
Test command returns supported values as compound value. 
11.4.3 Defined values 
<level>: 0~5  integer type value with manufacturer specific range (smallest value 
represents the lowest sound level). 0 means mute. Default value is 2. Resetting the 
module will not affect the value. Module updating will reset the value to default value. 
11.5 +CMUT -Switch mute status   
11.5.1 command syntax 
Command 
Possible response(s) 
+CMUT=<n> 
<CR><LF>OK<CR><LF> 
<CR><LF>+CME ERROR: <err><CR><LF> 
<CR><LF>OK<CR><LF> 
+CMUT? 
<CR><LF>+CMUT: <n><CR><LF> 
<CR><LF>OK<CR><LF> 
<CR><LF>+CME ERROR: <err><CR><LF> 
+CMUT=? 
<CR><LF>+CMUT: (list of supported <n>s) 
<CR><LF><CR><LF>OK<CR><LF> 
 
11.5.2 Description 
This command is used to enable and disable the uplink voice muting during a voice 
call.   
Test command returns supported values as compound value.   
11.5.3 Defined values 
<n>: 
 
mute off (default) 
 
mute on