RAD Data comm IPmux-11 Manuel D’Utilisation

Page de 148
Chapter 6  Troubleshooting and Diagnostics 
Installation and Operation Manual 
6-20 Testing 
IPmux-11
 
IPmux-11 Ver. 2.00 
•  Define loop-up code length (Length of the code to be sent by the TDM device 
in order to activate a loopback) 
•  Define loop-up code (Code to be sent by the TDM device in order to activate 
a loopback) 
•  Define loop-down code length (Length of the code to be sent by the TDM 
device in order to deactivate a loopback) 
•  Define loop-up code (Code to be sent by the TDM device in order to 
deactivate a loopback). 
Diagnostics>Loopback (T1)>Inband Loop Detection 
1. Loop Location                 > (Local System) 
2. Loop up length[1 - 8]         ... (5) 
3. Loop up code[Hex]             ... (10) 
4. Loop down length[1 - 8]       ... (3) 
5. Loop down code[Hex]           ... (4) 
 
Please select item <1 to 5> 
ESC-prev.menu; !-main menu; &-exit                                   1 Mngr/s 
Figure 6-16.  Inband Loop Detection Menu 
Pinging IP Hosts  
You can ping a remote IP host to check the IPmux-11 IP connectivity.  
 
To ping an IP host: 
1.  From the Diagnostics menu (
), select Ping
The Ping menu appears (see 
2.  From the Ping menu, configure the following: 
 
Destination IP Address (IP address of the host that you intend to ping): 
0.0.0.0 to 255.255.255.255. 
 
VLAN Tagging: 
 
Enable (VLAN tagging is enabled) 
 
Disable (VLAN tagging is disabled) 
 
VLAN ID: 1–4095 
 
VLAN Priority: 0–7 
 
The VLAN ID and VLAN Priority configuration is available only if the VLAN tagging is 
enabled. 
 
 
Number of frames to send: 14. 
3. Select Ping to start sending pings. 
Note