RAD Data comm IPmux-11 Manuel D’Utilisation

Page de 148
Quick Start Guide 
Installation and Operation Manual 
Configuring IPmux-11 
IPmux-11 Ver. 2.00 
Configuring the IP Management Parameters 
The host IP address, subnet mask and default gateway IP address must be 
configured via an ASCII terminal. 
 
To configure the IP management parameters: 
•  From the Host IP menu (Main > Configuration > System Host IP), select 
an IP address of the IPmux-11 host. 
Configuring E1 and T1 at the Physical Level 
E1 and T1 interface must be configured at the physical level first. 
 
To configure E1 and T1 at the physical level: 
•  From the TDM Configuration menu (Configuration > Physical layer > TDM 
configuration
), configure the necessary parameters of the E1 or T1 services. 
Configuring Bundle Connections 
The E1/T1 timeslots must be assigned to a bundle. The bundle must be sent to the 
remote IP address and be connected to one of the destination bundles. 
 
To assign timeslots to a bundle: 
•  From the DS0 Bundle Configuration menu (Main > Configuration > 
Connection
 > DS0 bundle configuration), assign desired timeslots to a 
bundle by setting them to 1
 
To connect a bundle: 
•  From the Bundle Connection Configuration menu (Main > Configuration > 
Connection
 > Bundle connection configuration), set the following: 
 
Destination IP address 
 
Destination bundle. 
Configuring the Internal Bridge 
 
To configure the Ethernet policy for the internal bridge ports: 
•  From the ETH Policy Configuration menu (Main Configuration > Bridge > 
Bridge policy configuration
), do the following: 
 
Specify bridge port operation mode 
 
Set default VLAN ID 
 
Set default VLAN priority 
 
Select rate limit for each port. 
 
To configure VLANs for the internal bridge ports: 
•  From the VLAN Table Configuration menu (Main Configuration > Bridge 
> VLAN table configuration), assign VLANs for each bridge port, if necessary.