1  GENLOCK IN connector (BNC)
Use this connector to input a reference signal to 
genlock the camera unit or externally lock the time 
code. The subcarrier of the VBS signal output by 
the VIDEO OUT connector of the camera cannot be 
externally locked.
For details, refer to [Externally Locking the Time Code] 
(page 62).
2  TC IN connector (BNC)
To externally lock the time code, input a reference time 
code to this connector.
For details, refer to [Externally Locking the Time Code] 
(page 62).
3  TC OUT connector (BNC)
Connect this connector to the time code input (TC IN) of 
the external device to lock the time code of that device 
to the time code of the AG-HPX300P.
For details, refer to [Outputting the time code externally] 
(page 63).
4  HOLD button
Pressing this button instantly freezes the time data 
indication on the counter. Note that time code 
generation continues. Pressing the button again restarts 
the counter.
This function allows you to check the time code or 
counter value of a recorded scene.
5  RESET button
Use this button to reset the counter value on the time 
code display to 0.
Pressing this button with the TCG switch positioned at 
[SET] when the TC PRESET screen and UB PRESET 
screen are open, resets all set values to 0. Use the 
Cursor SET button to PRESET.
6  COUNTER (counter display selector) button
Each press of the button displays the counter value, 
time code, user bit and frame rate data in the viewfinder 
and LCD display.
7  TCG (time code selector) switch
Use this switch to set the running mode of the built-in 
time code generator.
F-RUN: 
  Select this position to continuously advance 
the time code independently of P2 card 
recording status. Use this position to 
synchronize the time code with the time of 
day, or to externally lock the time code.
SET: 
 
Select this position to set the time code or 
user bits.
R-RUN: 
  Select this position to advance the time 
code only during recording. The time code 
is continuously recorded during normal 
recording. But deleting clips and setting a 
24P/24PA frame rate to continue recording of 
clips that are not 24P/24PA clips may break 
the sequence of time code recording.
 NOTE
Always use the CURSOR and SET buttons to set the time 
code and user bits. The JOG dial button cannot be used for 
this purpose.
8  CURSOR and SET buttons
Use these buttons to set the time code and user bits. 
The four triangular buttons are cursor buttons and the 
square center button is the SET button.
For details, refer to [Setting Time Data] (page 56).