Mitsubishi Electronics QD75MH1 Manuel D’Utilisation

Page de 838
 
 
 
11 - 9 
MELSEC-Q
 
11   MANUAL CONTROL 
 
Setting item 
Setting requirement 
Factory-set initial value 
(setting details) 
 Pr.25    Acceleration time 1 (Unit: ms) 
 
1000 
 Pr.26    Acceleration time 2 (Unit: ms) 
 
1000 
 Pr.27    Acceleration time 3 (Unit: ms) 
 
1000 
 Pr.28    Deceleration time 1 (Unit: ms) 
 
1000 
 Pr.29    Deceleration time 2 (Unit: ms) 
 
1000 
 Pr.30   Deceleration time 3 (Unit: ms) 
 
1000 
 Pr.31   JOG speed limit value (Unit: PLS/s) 
 
20000 
 Pr.32   JOG operation acceleration time selection 
 
0 (acceleration time 0) 
 Pr.33   JOG operation deceleration time selection 
 
0 (deceleration time 0) 
 Pr.34   Acceleration/deceleration process selection 
 
0 (trapezoidal acceleration/ 
deceleration processing) 
 Pr.35   S-pattern proportion (Unit: %) 
 
100 
 Pr.36   Sudden stop deceleration time (Unit: ms) 
 
1000 
 Pr.37   Stop group 1 sudden stop selection  
 
0 (deceleration stop) 
 Pr.38   Stop group 2 sudden stop selection 
 
0 (deceleration stop) 
Positioning parameters 
 Pr.39   Stop group 3 sudden stop selection 
 
0 (deceleration stop) 
 
  :  Setting always required.  
  :  Set according to requirements (Leave set to the initial value when not used.)