Mitsubishi Electronics QD75MH1 Manuel D’Utilisation

Page de 838
 
 
 
11 - 8 
MELSEC-Q
 
11   MANUAL CONTROL 
 
11.2.3 Setting the required parameters for JOG operation 
The "Positioning parameters" must be set to carry out JOG operation. 
The following table shows the setting items of the required parameters for carrying out 
JOG operation. When only JOG operation will be carried out, no parameters other than 
those shown below need to be set. (Use the initial values or setting values within a 
range where no error occurs for trouble-free operation.)  
 
Setting item 
Setting requirement 
Factory-set initial value 
(setting details) 
 Pr.1    Unit setting 
 
3 (PLS) 
 Pr.2    No. of pulses per rotation (Ap) (Unit: PLS) 
 
20000 
 Pr.3    Movement amount per rotation (Al) (Unit: PLS) 
 
20000 
 Pr.4    Unit magnification (Am) 
 
1 (1 times) 
 Pr.7   Bias speed at start (Unit: PLS/s) 
 
 Pr.8   Speed limit value (Unit: PLS/s) 
 
200000 
 Pr.9   Acceleration time 0 (Unit: PLS/s) 
 
1000 
 Pr.10    Deceleration time 0 (Unit: PLS/s) 
 
1000 
 Pr.11    Backlash compensation amount (Unit: PLS) 
 
 Pr.12    Software stroke limit upper limit value (Unit: PLS) 
 
2147483647 
 Pr.13    Software stroke limit lower limit value (Unit: PLS) 
 
–2147483648 
 Pr.14    Software stroke limit selection 
 
0 (current feed value) 
 Pr.15    Software stroke limit valid/invalid setting 
 
0 (valid) 
Positioning parameters 
 Pr.17    Torque limit setting value (Unit: %) 
 
300 
 
  :  Setting always required.  
  :  Set according to requirements (Leave set to the initial value when not used.)  
 
REMARK 
 Positioning parameter settings work in common for all control using the QD75MH. 
When carrying out other control ("major positioning control", "high-level positioning 
control", "OPR positioning control"), the respective setting items must also be 
matched and set. 
 Parameters are set for each axis. 
 Refer to Chapter 5 "Data Used for Positioning Control" for setting details.