Avaya 555-233-116 Manuel D’Utilisation

Page de 246
1145B power supply
Issue 4   October 2002
35
555-233-116
Installing the 1146 power distribution unit
1. Insert and securely tighten the two supplied #8-32 x 1/2-in. shoulder 
screws (they have an unthreaded section at the top) into the top holes 
designated for 1146 Power Distribution Unit on the bottom plate. Mount the 
unit on these two shoulder screws, using the key holes on the back of the 
unit.
2. Secure the unit by inserting the #8-32 x 1 in. screw through the bottom of 
the unit (just above the wire clips) into the plate and tighten.
3. Set the battery back-up switch option to the 1-32 (down) position to provide 
battery back-up to all outputs.
4. Connect the power distribution unit to the power supply with the power 
cable. Refer to the power supply’s right-side label to locate the output 
power connection.
Installing and wiring the battery
Two types of backup batteries can be used:
To install the battery, proceed as follows.
1. Loosely insert two #10-32 x 1/2-in. shoulder screws in the battery-mounting 
holes at the top of the wall mounting plate.
2. Place the keyhole slots in the battery bracket on these two screws. Make 
sure the label on the battery is visible.
The battery cord exits from the right side of the bracket.
3. Tighten the screws securely.
4. Plug the battery cord into the right rear receptacle on the power supply. 
The right-side label indicates the rear receptacle.
Table 6.
Back-Up Batteries
Battery
Rating
1148B
2.5 amp-hours
1149B
5 amp-hours