Auxiliary power supplies
555-233-116
36
Issue 4   October 2002 
Installing the expanded power distribution unit
You can install a second power-distribution unit for additional 8400- and 8500-
series terminals.
!
CAUTION:
Total power cannot exceed 200 W. Consult the chart below for permissible 
terminal installations.
Each expanded power distribution unit kit supplies the following items:
One power distribution unit 
One T-cable
Two #8-32 x 1/2-in. shoulder screws
One #8-32 x 1 in. screw
One spacer bracket
See 
 while installing the power distribution unit:
1. Fasten the spacer bracket to the mounting plate with the #8-32 x 1/2-in. 
shoulder screws.
The spacer bracket is not shown in the figure. It is behind the top power 
distribution unit.
2. Slide the keyhole slots in the power distribution unit over the shoulder 
screws.
3. Insert the #8-32 x 1 in. screw through the distribution unit, through the 
spacer bracket, and into the plate. Tighten the screw.
The mounting hole is located just above the wire clip.
4. Set the battery back-up switch to the 1-32 (down) position.
5. Power-down the 1145B as described on the label on the side of the unit.
Table 7.
Permissible terminal installations (total power < 200 W)
Terminal mix
Maximum numbers
Notes
7500-series + 8500-series ISDN
24 + 24
7400-series + 8400-series DCP
24 + 24
8400-series DCP
74
7400-series DCP
74
Average power per 
terminal must be 
less than 3.126 W