Coaxitron
EXTENDED – Use when your system has moveable cameras controlled by 32-bit
Coaxitron receivers, such as Esprit™, Intercept, Spectra, IRD/ERD2000 Series, and
LRD41C21/LRD41C22 Series.
OFF – Use when your system has fixed cameras only.
STANDARD – Use when your system has moveable cameras controlled by 15-bit
Coaxitron receivers, such as the CX9000 Series, the PT7700, and the ED25/27/28/29.
Dwell
Select the dwell rate for alarms in seconds. The default is two seconds.
4.
To program another camera, go to MAIN MENU and press the +/- button.
(Or, you can do the following: Move to the next camera menu by positioning the cursor
on the camera number at the top of the menu screen and pressing the +/- button. This
takes you to the next camera menu.)
5.
When you finish all the changes you want to make, go to EXIT.
6.
Press the +/- button to exit programming mode.
SEQUENCE SETUP (SEQUENCE BUTTON)
Figure 25.  Camera Sequence Menu
Sequencing can be programmed in full-screen or four-camera display. LEDs above the
camera buttons will illuminate to indicate which cameras are being displayed.
To program camera sequencing:
1.
Select SEQUENCE SETUP on the Main Selection Menu or press the SEQUENCE
button for about three seconds until the Sequence menu appears. Type the password,
if requested. The currently selected menu item blinks.
2.
Use the arrow buttons to move between items on the screen.
3.
When the menu item you desire is highlighted (blinking), press the +/- button to cycle
through the options to select the one you want.
Seconds
Set the dwell rate for each camera and the quad display. Select 0 to skip a camera or
the quad display.
4.
When you finish all the changes you want to make, go to EXIT.
5.
Press the +/- button to exit programming mode.
FULL
 
SCREEN
 
SEQUENCE
 
SETTINGS
CAMERA 1
CAMERA 2
CAMERA 3
CAMERA 4
MAIN MENU
EXIT
02
02
02
02
SEC
QUAD                               MAIN MONITOR ONLY
02
00887