Motorola G24 Manuale Utente

Pagina di 642
Modem Configuration and Profile
3-276
 AT Commands Reference Manual
December  31, 2007
Example
ATE?
001
OK
X, Result Code Selection and Call Progress Monitoring Control 
This command defines the CONNECT result code format. It determines whether or not the G24 
transmits particular result codes to the user. It also controls whether the G24 verifies the presence 
of dial tone when it first goes off-hook to begin dialing, and whether the engaged tone (busy 
signal) detection is enabled.
The following table shows the X parameters.
Example
ATX?
000
OK
Command Type
Syntax
Response/Action
Remarks
Set
ATX<value>
OK
or:
+CME ERROR: <err>
The Set command sets the result code 
and call progress monitoring control.
Read
ATX?
<current value>
Test
The Test command for X is not defined 
by ITU, and therefore is not supported 
by the G24. The G24 returns an error.
Table 3-184: X Parameters
<Parameter>
Description
<value>
0
CONNECT result code given upon entering online data state:
Dial tone detection - Disabled
Busy detection - Disabled
1
CONNECT <text> result code given upon entering online data state:
Dial tone detection - Disabled
Busy detection - Disabled
2
CONNECT <text> result code given upon entering online data state:
Dial tone detection - Enabled 
Busy detection - Disabled
3
CONNECT <text> result code given upon entering online data state:
Dial tone detection - Disabled 
Busy detection - Enabled
4
CONNECT <text> result code given upon entering online data state: 
Dial tone detection - Enabled
Busy detection - Enabled
The default value is 0.