Installation 
22 
Marathon Series FA/FR 
2.  Install all electronics wiring according to the applicable sections 
, 
, and 
! 
3.  Plug  the  RS485/RS232  interface  converter  into  your  computer’s  serial  port,  or  attach  it  to  a 
serial cable connected to the computer! Use 9 pin to 25 pin converter if necessary! 
4.  If the 9 VDC power supply is used, apply power to the RS485/RS232 converter! 
5.  Apply power to the FA/FR sensor! 
6.  Turn on your computer! 
 
You need to make sure another serial device (e.g. an internal modem) is not using the 
identical COM‐port at the same time!
 
 
Always make all electrical connections before applying power to the FA/FR sensor! Do 
not change RS485 or power connections on the RS485/RS232 converter while the FA/FR 
sensor has power applied, as this may cause damage to the Interface converter! 
5.7.1 Multidrop Installation (4‐Wire) 
In 4‐wire multidrop installations the data can be transferred in both directions, from sensor to PC and 
reverse. 
 
Figure 18: Wiring for 4‐Wire Sensor Setup 
5.7.2 Multidrop Installation (2‐Wire) 
Using the 2‐wire installation saves 2 wires in comparison to the 4‐wire installation. The disadvantage 
is, that the data transfer can be only in one direction at the same time. 
To Computer 
RS232 serial port 
RS232/485 
Interface Converter 
XXX485CVT… 
Electronics Housing 
9 VDC power supply or ...
24 VDC power supply 
from RxB 
from RxA 
from TxB 
from TxA 
Ground 
+24 VDC (optional)