2. EXAMPLE OF OPERATION USING PROGRAMMING GUI 
This chapter explains a series of basic FP5 operations using the programming GUI, taking a case where the RH850/F1L 
is used as the target device as an example.  This chapter covers how to start the system, execute the 
[Autoprocedure(E.P.)] command and program the target device. 
 
•  Series of operations described in this chapter: 
 
The operation conditions for this chapter are as follows. 
Host PC interface:   
 
 
 
USB 
Programming area:  
 
 
 
Divided by 2, Area 0 
Target device:  
 
 
 
 
R7F701023 (RH850/F1L) (on evaluation board) 
Supply oscillator:   
 
 
 
24MHz 
Communication interface to device: 
2 wire UART @ 2Mbps 
Security mode: 
 
 
 
 
Command protection mode 
Operation area: 
 
 
 
 
All blocks 
Command protection: 
 
 
 
Not used 
 
The operation steps described in this chapter are as follows 
(1)  Installation of programming GUI and USB driver 
(2)  Installation of PR5 file 
(3)  System connection 
(4)  Connection of target system 
(5)  Startup of programming GUI 
(6)  Setting of programming environment 
(7)  Execution of [Autoprocedure(E.P.)] command 
(8)  System shutdown 
 
(1)  Installation of programming GUI and USB driver 
Refer to Common 3 SOFTWARE INSTALLATION and install the programming GUI and USB driver in the host PC. 
 
(2)  Installation of PR5 file 
Refer to Common 3 SOFTWARE INSTALLATION , download the PR5 file for the R7F701023 and copy it to the 
FP5_PRJ folder in the programming GUI installation folder.  
 
(3)  System connection 
<1>  Connect the USB connector of the FP5 to the USB port on the host PC using a USB cable. 
<2>  Plug the FP5 power supply connector into the AC outlet (100 to 240 V) using the AC adaptor. 
<3>  Press the POWER button on the FP5 to turn on power.  Do not connect the program adaptor (target device) before 
turning on power.  Confirm that the POWER LED on the FP5 is off and that ‘Commands >’ is displayed in the message 
display, indicating that the FP5 is ready for operation.  If not, the cause may be a defect in the FP5, so consult a Renesas 
Electronics sales representative or distributor. 
 
(4)  Connection of target system 
Be sure to turn on the FP5 power before connecting the target system. 
 
<1> Connect the FP5 GND connector to the target system using a GND cable. 
 
Note 
The FP5 and target system may be damaged if the voltage between the FP5 GND and the target system GND is 
different.  Use the GND cable to match the voltage before connecting the target cable. 
 
<2>  Connect the FP5 target connector to the target system using the target cable. 
 
Note 
Connect the target system before supplying V