Enterasys Networks X009-U Manuale Utente

Pagina di 86
Installing and Removing a Power Supply
Matrix X4-C Chassis Installation Guide 3-15
Removing a Power Supply
To remove a power supply, proceed as follows:
1.
Attach the anti‐static wrist strap as described in 
” on page 3‐11 before handling the power supply module.
2.
Unplug the associated power cord from the 20A/100‐125 Vac (or 8A/200‐240 Vac) outlet.
3.
Unplug the power cord from the AC inlet (associated with the power supply you are 
removing) at the back of the chassis, as shown in 
. For example, inlet AC1 
correlates with PS1.
Figure 3-15  Removing the AC Inlet Power Cord
4.
Loosen screws securing the power supply vent plate to the chassis and remove the vent plate.
5.
Unscrew the captive screw to release the power supply from the chassis.
6.
Remove the power supply by grasping the handle and pulling it straight out of the chassis.
7.
Fasten a coverplate over the empty slot.
8.
Reinstall the vent plate.
Inlet power cord
AC inlet (AC1)
Caution: If you plan to operate the chassis with only one power supply, be sure to install the 
coverplate in place of the removed power supply to contain EMI radiation and ensure proper air 
circulation.
Precaución: Si desea trabajar sólo con una fuente de poder, no olvide colocar la tapa en el 
compartimiento de la fuente de poder que haya eliminado, para reducir la interferencia 
electromagnética y para asegurar una buena ventilación.
1
2
AC INLET 3
100 - 125V ~ 15A
200 - 240V ~ 8A
50/60 Hz
AC INLET 2
100 - 125V ~ 15A
200 - 240V ~ 8A
50/60 Hz
AC INLET 1
100 - 125V ~ 15A
200 - 240V ~ 8A
50/60 Hz
CAUTION:  THIS UNIT MAY HAVE MORE THAN ONE
POWER SUPPLY CORD.  DISCONNECT THREE (3)
POWER SUPPLY CORDS BEFORE SERVICING TO
AVOID ELECTRIC SHOCK.
VORSICHT:  DIESES GERÄT HAT MEHR ALS EINEN
NETZANSSCHLUß.  TRENNEN SIE VOR
WARTUNGSARBEITEN DIE 3 NETZANSCHLÜSSE VOM
NETZ, UM ELEKTRISCHE SCHLÄGE ZU VERMEIDEN.