NEC 2400IMX Manuale Utente

Pagina di 485
NDA-24282
CHAPTER 2
Page 9
Revision 1.0
GENERAL INFORMATION
2.3.1
SYSTEM CAPACITY
CallCenterWorX-Enterprise (ACD) system capacity can be upgraded by installing the ACD Option Service
Software (standard) for extending ACD capacity.
For the procedure to link with the Optional Service Software, refer to Chapter 4 “System Startup” in the
Installation Manual.
Note:
Due to the amount of memory allocated to the ACD database, use consecutive numbering when possible to
gain the maximum number of pilot numbers, ACD myline, ACD line, IVR parts, and analog access codes
available.
Table 2-1  CallCenterWorX-Enterprise (I) ACD Capacities 
System Components
25-1,000 Seats
Version (I4.01.00.000)
Analog Agent Access Codes
4,000 *
Announcement Routes
58
Call Active (simultaneous calls)
6,000
Call Control Vectors (20 steps each)
1,200
Holiday Schedules per Tenant
3
IVR Ports
400
Logon IDs (9 digits maximum)
7,000
Personal Pilot Numbers
4,000 *
Pilot Numbers
4,000 *
Priority Level
250
Splits
900
Splits per Agent
16
Station Calls
500
TCP/IP Clients
8
Tenants
10
Transfer to PBX Numbers
1,200
Trunk Groups
255
*  
Note:
 Personal Pilots, Pilots, and Analog Access Codes cannot exceed 4,000.