Honeywell 16103 Manuale Utente

Pagina di 18
8
Menu 11 - Omit Zones
This function allows a user to temporarily disable a detection zone from the system (for
example, to disable a movement detector when a dog is left in the house). Zone omits last for
one set period only and automatically switch off when the system is unset. On entering the
menu option, the first omittable zone is displayed. The A> and B< scroll keys can be used to
select the different zones in turn. To omit a particular zone, scroll to the zone so that it is
displayed on screen. Press the # key and the message in the bottom left corner will change to
‘Omitted’. Select other zones as required in a similar way. When all zones have been selected as
required, press ent to begin setting with the omitted zones, or esc to escape back out and save
the omitted zones for setting later.
Menu 12 - Timed Set
This option initiates the timed full setting routine, identical to typing a PIN code and pressing
the A> key.
Menu 13 - Part Set
This menu option initiates the timed Part Set routine as described earlier.
Menu 14 - Night Set
This menu option initiates the timed Night Set routine as described earlier.
Menu 15 - Chime
This menu option allows one or more zones to be put into Chime mode. When chime mode is
enabled for a zone, the internal sounders will beep twice each time the detector on that zone is
activated. This function can be useful, for example, in a shop to indicate when a customer has
come through the front door.
Menu 21 - Zone Status
This menu option is used to show the status of each individual detection zone on the system.
On entering the option, the first system zone will be displayed as shown:
On the top row, the zone address is shown along with the zone function which toggles with
the current status (open, closed, etc).
NOTE:
If groups are enabled, the group will be shown.
1001
1001
1001
1001
1001
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
ZONE1
ZONE1
ZONE1
ZONE1
ZONE1
status
1001
1001
1001
1001
1001
FINAL
FINAL
FINAL
FINAL
FINAL
ZONE1
ZONE1
ZONE1
ZONE1
ZONE1
function
1001G1
1001G1
1001G1
1001G1
1001G1
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
ZONE1
ZONE1
ZONE1
ZONE1
ZONE1
group
On the bottom row, the description of the zone is shown to aid identification.
Using the A> and B< scroll keys, any of the zones on the system can be displayed.
Additionally, pressing the # key will show additional diagnostic information for that zone. This
may be required for fault finding when talking to the alarm installation company by phone.