595-5498-09
INSTALLATION
For best performance, mount the fixture about 7ft (2.1 
m) above the ground.
 
Turn the power to the lighting circuit off at the 
fuse or circuit breaker box.
  Remove the existing light fixture.
  Install  the  mounting  strap 
into  the  junction  box.  Ori-
entation  of  the  strap  may 
be different.
  Strip  about  5/8  in.  (15  mm) 
insulation off of the existing 
junction box wiring.
  Connect the 
white (neutral) junction box wire to the 
white Entryway Light wire. Twist the wires together 
and secure with a wire connector.
  Connect  the 
green  or 
bare (ground) mounting 
strap wire to a grounded 
wire  or  to  a  grounded 
metal box.
  Connect  the 
black 
(hot)  junction  box 
wire to the 
black En-
tryway Light wire.
  Install the mounting stem into the strap so 
that it extends out about 3/4 in. (19 mm).
  Install the fixture over 
the mounting stem.
  Install and tighten the 
mounting stem nut.
Holding Screw 
for Globe or Jar
 
Caulk the back edge of the light and mounting 
surface
 with silicone weather sealant.
  Install a 60 Watt maximum light bulb into the lamp 
holder. Do not overtighten. 
Higher wattages will 
void warranty.
  Loosen the front holding screw so the globe or jar 
cover  can  be  installed.  Secure  by  tightening  the 
screw. 