TEST AND ADJUSTMENT
 
Turn on the circuit breaker and light switch.
Avoid aiming the control at:
•  Objects that change temperature rapidly, such as 
heat-
ing vents or air conditioners. These heat sources 
could cause false triggering.
•  Areas where 
pets or traffic may trigger the control.
•  
Nearby large, light-colored objects reflecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.
110°
30 ft (9.1m)
The detector is less sensitive to motion directly towards 
it and more sensitive to across motion. 
 7ft
 (2.1 m)
Maximum Range
Maximum
Coverage Angle
  Rotate the sensor base left 
and right to aim the sensor. 
Adjust  the  sensor  eye  up 
and down to obtain desired 
coverage range.
  Walk  through  the  coverage 
area  noting  where  you  are 
when the lights turn on. Move 
the  sensor  head  up,  down, 
or  sideways  to  change  the 
coverage area.
  Set SENSITIVITY as needed. 
Too  much  sensitivity  may 
increase false triggering.
  Set  the  amount  of TIME  the 
lights stay on after motion is de-
tected (1, 5, or 10 minutes).
In the test position shown above, the light will turn 
on for 5 seconds each time motion is detected
 dur-
ing both daylight and darkness.
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 30 ft (9.1 m) [varies with 
surrounding temperature].
Sensing Angle . . . . . . . . Up to 110°
Electrical Load . . . . . . . . Up to 60 Watt Maximum In-
candescent
Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST,  AUTO  and  MANUAL 
OVERRIDE
Time Delay  . . . . . . . . . . 1, 5, 10 minutes
Sensitivity  . . . . . . . . . . . Adjustable 
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features in 
products previously sold.
ON-TIME
SENS
TEST 1 5 10
MIN  MAX
Bottom of Sensor
Least Sensitive
Most Sensitive
Sensor
Motion
Motion
NOTE:  Sensor has a 1 
1
/
2
 minute calibration period 
before it will detect motion. When first turned 
on, wait 1 
1
/
2
 minutes. 
Aim Sensor 
Down for Short 
Coverage
Aim Sensor 
Higher for Long 
Coverage
  For aiming, turn the SENSITIVITY (SENS) control 
to the mid position and the ON-TIME control to the 
TEST position.