TEST AND ADJUSTMENT
 
Turn on the circuit breaker and light switch.
Motion
Motion
The detector is most sensitive to motion across its field 
of view.
  Loosen the clamp screw in the 
sensor  ball  joint  and  gently 
rotate the sensor.
  Walk  through  the  coverage 
area  noting  where  you  are 
when the lights turn on (also, 
the LED will flash several times 
when motion is detected). Move 
the sensor head up, down, or 
sideways to change the cover-
age area. 
Keep the sensor at 
least 1" (2.5 cm) away from 
the lamps.
  Adjust the RANGE as needed. 
RANGE  set  too  high  may 
increase false triggering.
 
Secure the sensor head by 
tightening the clamp screw.
 
Do not overtighten the screw.
  Set the amount of TIME you want the lights to stay 
on after motion is detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with 
surrounding temperature].
Sensing Angle . . . . . . Up to 150°
Electrical Load . . . . . . Up  to  300  Watt  Maximum  In-
candescent  [Up  to  150  Watt 
maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST,  AUTO  and  MANUAL 
MODE
Time Delay  . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable 
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features 
in products previously sold.
NOTE:  Sensor  has  a  1 
1
/
2
  minute  warm  up  period 
before it will detect motion. When first turned 
on, wait 1 
1
/
2
 minutes.
RANGE
10 5 1 TEST
ON-TIME
Bottom of Sensor
Avoid aiming the control at:
•  Objects  that  change  temperature  rapidly,  such  as 
heating  vents  and  air  conditioners.  These  heat 
sources could cause false triggering.
•  Areas where 
pets or traffic may trigger the control.
•  
Nearby large, light-colored objects reflecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.
70 ft.
(21 m)
8 ft. 
(2.4 m)
150°
MIN 
MAX
  Least Sensitive 
 Most Sensitive
Sensor
Warning - Risk of fire. Do not aim the lamps at a 
combustible surface within 3 ft. (1 m).
 
Maximum Range 
Maximum
 
 
Coverage Angle
Clamp 
Screw
 
Ball 
Joint
Aim Sensor 
Down for Short 
Coverage
Aim Sensor 
Higher for Long 
Coverage
  Turn the RANGE control to the mid position and the 
ON-TIME control to the TEST position.