Burley G4237/8 Manuale Utente

Pagina di 15
 
- 4 - 
4.2  Decide  upon  the  route  for  the 
gas supply and if this is to be a 
concealed  supply,  select  a 
suitable  hole  in  the  fire  box, 
remove  the  knockout  and  lay 
in  the  supply  as  required.  Fit 
the rubber grommet around the gas pipe entry to the appliance and seal.  
Before working on pipework, plug the ends to prevent the entry of debris. Decide upon the route 
for the gas and lay pipework as required. If the gas pipe passes through a wall, cavity or un-vented 
void then there should be no joins in this area and the pipes should be fully sleeved. 
Note  the  supply  can  be  either  concealed  through  the  holes  in  the  appliance  sides  and  back  or 
surface  fitted  over  the  hearth  and  where  pipes  pass  through  walls  they  must  be  sleeved.  In  the 
case of remote control fires  and  wall  mounted  fires,  all  of  the  possible  gas  supply  positions  may 
not  be  available.  Before  pushing  gas  pipes  through  walls,  seal  the  pipe  ends  to  prevent  debris 
entering the pipes. 
.  
Before connecting any pipes to the appliance, fully purge pipes of debris or swarf etc. and connect 
the  gas  supply  to  the  8mm  elbow  on  the  fire.  Leak  test  the  supply  using  an  approved  method. 
Note: An isolating valve must be situated near the appliance for servicing.  
 
5.0 INSTALLATION INSTRUCTIONS 
Note: The fires must be used as supplied with the smaller 60mm spacer fitted, failure to do so 
will  make  fitting  the  decorative  case  impossible  &  may  overheat  the  fireplace  and  thus 
invalidate  the  warranty.  Burley  manufacture  purpose  made  surrounds,  which  have  been 
specially tested with the appliance for compatibility.  The following guidelines must be adhered 
to. 
The hearth must be a minimum of 12mm thick with the top surface standing a minimum of 50mm 
above  surrounding  floor  level  or  surrounded  by  a  raised  fixed  fender  of  50mm  high.  The  hearth 
must extend a minimum of 100mm in front of the fire bed and 50mm either side of the appliance 
giving an overall width of 732mm.  
Closure plate tape and foam seals are unsuitable for fixing and sealing the fire into place. Always 
fix with the fixing cables, the wall brackets or through the base of the fire. 
 
5.1 
INSTALLATION METHODS 
The appliance is a flueless visual flame heater designed to be installed in a number of ways, both 
freestanding, inset and wall or hearth mounted. This provides a great deal of flexibility. It can also 
be  fitted  without  need  for  a  fire  surround  or  back  panel,  provided  it  is  fitted  against  a  non 
combustible surface. Any combustible materials directly behind the fire frame or back panel must 
be removed and replaced with suitable non combustible material such as superlux board, cement 
or similar. 
The  fire  surround,  back  panel,  hearth  and  all  paints  /  lacquers  etc  must  be  of  minimum  150
o
rating. Please ensure this is the case and if necessary check with the manufacturer, as we cannot 
be held responsible for subsequent damage. 
Note that paint and wallcoverings on surfaces subject to heat can discolour and great care should 
be taken when choosing wall coverings. 
5.2 
METHOD ONE - FREESTANDING ON HEARTH OR WALL MOUNTED FULLY OUTSET 
 
This method allows for surface / wall fixing of the fire using the deep spacers and deep brackets 
supplied without the need for insetting into a fire opening. The appliance gets very hot and could 
cause  burns  therefore  if  wall  mounting  without  a  hearth  then  care  should  be  taken  to  avoid 
gangways  and  congested  areas.  Care  should  also  be  taken  with  curtains  and  soft  furnishings  to