Burley G4237/8 Manuale Utente

Pagina di 15
 
- 5 - 
ensure there is no possibility of them touching the appliance. 
 
632mm
197mm
590mm
 
 
Overall dimensions are as shown. 
 
Hearths  -  For  hearth  mounting  (or  if  the  fire  is  less  than  200mm  above  the  ground)  then  the 
hearth  must  protrude  at  least  100mm  in  front  of  the  fire  and  50mm  to  either  side.  A  minimum 
hearth of 732mm wide x 300mm deep is required, the hearth must be a minimum of 12mm thick 
and be of a non combustible material. The surface on which the appliance is to stand must be flat, 
level  and  square  to  the  back  panel.  Failure  to  observe  this  could  result  in  the  appliance  leaning 
away from the fireplace.  
If  the  appliance  is  fitted  on  the  wall,  more  than  200mm  above  the  ground  then  a  hearth  is  not 
required. 
 
Chimneys & under grate draught devices – To prevent draught from affecting the stability of the 
appliance flames, all chimney openings and undergrate draught devices within 1 metre of the fire 
must be blocked off. 
 
Fixing - The appliance should be secured to the wall using the fixing brackets on the flange of the 
appliance. If it is to be mounted above the ground, care should be taken to ensure the wall is able 
to  take  the  weight  of  the  appliance  and  that  the  fixings  are  of  the  correct  type.  Use  all  6  screw 
holes in the brackets to attach to the wall. 
 
If the appliance is hearth mounted the fixing is intended to prevent the appliance from moving / 
toppling  and  it  is  permissible  just  to  use  2  holes  in  the  wall  brackets  or  to  drill  through  the 
appliance base and screw it to the floor. 
Do not fix the appliance directly to plasterboard as prolonged exposure to heat could affect it or 
the vapour layer behind. A layer of heat resistant board should be screwed to the wall instead. 
 
Fully purge pipes of air and any debris and connect the gas supply to the 8mm elbow on the fire. 
Leak test the supply using an approved method. Note: An isolating valve must be situated near the 
appliance 
for 
servicing. 
Site the thermostat at a suitable position where it will sense the room temperature.  
 
The  case  can  be  test  fitted  to  the  chassis  to  ensure  clearance.  The  gap  in  the  case  top  between 
grille and spacer slides over the top flange on the appliance. The bottom of the case has folded out 
brackets that slide over cut outs in the appliance chassis. 
 
The door on the appliance is secured with a magnet and it may be necessary to adjust the strength 
of the magnets grip. This can be done by bending the magnet holding bracket in or out to adjust. 
 
Remove case and place to one side.