CFM UVS43 Manuale Utente

Pagina di 20
10
Majestic Fireplaces
®
 UVC / UVS Vent-Free Heaters
20000135
Glass Information
(UVC Only)
Only glass approved by CFM Specialty 
Home Products should be used on this 
fireplace.
• 
The use of any non-approved replacement glass will 
void all product warranties.
• 
Care must be taken to avoid breakage of the glass.
• 
Do not operate appliance with glass front re-
moved, cracked or broken.
• 
Replacement glass (complete with gasket) is 
available through your CFM Specialty Home 
Products dealer and should only be installed by 
a licensed qualified service person.
 Louvre Removal
To remove the top 
louvre (grille), lift lou-
vre up and then out. 
(Fig. 12)
cleaner and warm water (we recommend gas fireplace 
glass cleaner). After that the glass should be cleaned 
two or three times during each heating season depend-
ing on the circumstances present.
Clean glass after first two weeks of opera-
tion.
Log Installation
Refer to Figures 14 and 15 for correct log placement.
1. Remove window frame assembly. (See "Window 
Frame Assembly" section)
2. Remove logs from packaging.
As with all plastic - these are not toys and 
should be kept away from children and 
infants.
3. Place rear log (BE8 or BF10) on rear bracket (ensure 
log is seated properly, leveled and centered to the 
unit), so it will not move from side to side and it is 
firmly positioned on the bracket.
4. Place front left log (BE6 or BF8) on top of burner, left 
side.  Use log's bottom holes to locate it onto the left 
bracket log locator studs.
5. Place front right log (BE7 or BF9) on top of burner, 
right side.  Use log's bottom holes to locate it onto 
the left bracket log locator studs.
6. Place ember material on top of burner. (See "Ember 
Material Placement" section).
Operating Instructions
FP444
Fig. 12   Louvre installation and 
removal.
1.
2.
Grille 
(Louvre)
Window Frame 
Assembly
FP1000
install glass
12/99
Fig. 13   Window Frame  installation and removal.
DV34-2
Glass removal
12/99
Clamps
Fireplace 
Front
Window 
Frame As-
sembly
Pull 
Clamp 
Hook
Push 
Clamp 
Hook
DV34-2
FP1000
Window 
Frame 
Assembly
Window Frame Assembly Removal
1. Shut off gas. (See Lighting Instructions)
2. Let the unit cool if it has been operating.
3. Remove top louvre. (See Top Louvre Removal)
4. Open the bottom louvre assembly.
5. Release the two clamps at the bottom of the window 
frame by pulling down on the clamp handles.
6. Lift off the window frame assembly as shown in 
Figure 13.
7. To reinstall window frame assembly follow the above 
procedure in reverse. (Fig. 13)
Glass Cleaning
It will be necessary to clean the glass periodically. Dur-
ing start-up, condensation, which is normal, forms on 
the inside of the glass and causes lint, dust and other 
airborne particles to cling to the glass surface. Also, 
initial paint curing may deposit a slight film on the glass. 
It is therefore recommended that the glass be cleaned 
two or three times with anon-ammonia household