Always check for gas leaks with a mild soap 
and water solution.  Do not use an open 
flame for leak testing.
The gas control is equipped with a captured screw type 
pressure test point, therefore it is not necessary to pro-
vide a 1/8" test point up stream of the control.
When using copper or flex connector use only approved 
fittings.  Always provide a union so the gas line can 
be easily disconnected for burner or fan servicing.  
See gas specification for pressure details and ratings. 
NOTE: If flex connector is used, it must be kept inside 
of the heater. (Fig. 7)
Fig. 8  Junction box (EB-1) hook-up.
FP298
INSTA VENT FREE
EB1 JUNCTION BOX
8/24/96
OUTSIDE
FRONT OF
 UNIT
INSIDE
FRONT OF
 UNIT
FP298
Electrical Box
Fastening Screws
Gas Inlet Hole
Gas Inlet Hole
Fig. 8  Wiring diagram.
FP394
FP394
WIRING DIAGRAM
11/20/96
Fan
Temperature 
Sensor
Speed 
Control
Black
White
Ground
Fig. 7   Typical gas supply installation.
FP297
FP297
INSTA VENT FREE
R MODEL GAS SUPPLY 
8/24/96
1/2" Gas Supply
1/2" x 3/8" Shut Off Valve
3/8" Nipple
3/8" Union
3/8" 
Nipple
Electrical Connection
 
When installed, the heater must be electri-
cally connected and grounded in accor-
dance with local codes or, in the absence 
of local codes:
U.S. Installations: Follow local codes and the National 
Electrical Code, ANSI/NFPA No. 70.
NOTE: 110/120 electric power is required to operate 
blower (fan).
Be sure to leave sufficient excess wire in case minor 
adjustments are required.
Any electrical re-wiring of this fan must be 
done by a qualified electrician.
Whether wiring directly to the fan junction box or into 
the EB1 (electrical receptacle box, P/N ZA1200) first 
ensure cable is secured using box connector.
Turn off all power before hook-up.
Hard (DIrect) Wire Hook-Up:
First connect ground wire to ground stud located on 
the base of either box.  Black wire from supply should 
connect to the variable speed switch.  Alternate speed 
switch wire connects to temperature sensor.  Alternate 
lead from sensor connects to fan.  Alternate fan con-
nects back to white supply wire. (Fig. 8)
EB1 (Receptacle) Hook-Up
1. Remove 2" knockout.  Slide the electrical box back 
plate into the back and bottom lances (clips) while fit-
ting the box connector into the knockout.  Fasten into 
place with fastening screws provided. (Fig. 9)
2. Connect the black positive wire to brass screw 
(polarized side) of the receptacle.  The white wire is 
connected to the chrome screw.  The ground wire is 
connected to the green ground screw of the recep-
tacle.  Fit the receptacle into the electrical box.
3. Screw the cover plate provided to the electrical box. 
Remote Wall Switch
CAUTION:  Do not wire millivolt remote wall 
switch for gas heater to a 120v power sup-
ply.
 For lighting instructions, see Page 12.
1. Thread wire through the electrical knockout 
located on either side of unit.  Do not cut wire or insu-
lation on metal edges.  Ensure that wire is protected. 
Run the other end to a conveniently located wall 
receptacle box.