GENERAL      All  furnaces  have  been  fire-tested  to  check  for 
proper operation.  This includes main burner flame, pilot flame, 
and gas control operation.  If the furnace fails to function on initial 
installation, it is advisable to re-check the following: 
1.  Inlet gas pressure.
2.  Type of gas being used and that shown on the rating plate.
The Service Department at Empire Comfort Systems, Inc. may be 
contacted to assist in servicing furnace.
Servicing the Pilot and Main Burner, Pilot Orifice, Thermopile 
and Main Burner Orifice  
Disconnect  the  gas  supply  at  the  inlet  to  the  control  valve.   
Remove the burner assembly to which the above components are 
attached.
Pilot Does Not Light 
With air in the gas line, such as when the furnace is first installed 
or was "OFF" all summer, the pilot flame may be too lean to ignite 
on the first few trials.  Turn the gas control knob to PILOT position 
and depress the gas control knob.  Hold the gas control knob down 
to bleed the line;
1.  Use lighter rod to light pilot with a match.
If Pilot Does Not Light By Any Means 
1.  Check gas control knob for being in the "Pilot" position.
2.  Check pilot adjustment for being full open (counterclockwise 
to open).
3.  If gas is available in the supply tubing, the pilot orifice and/or 
pilot burner is probably restricted by a spider web.  Clean 
pilot assembly and relight.
If Pilot Does Not Remain "On" After Releasing Gas Control 
Knob 
1.  Follow instructions and hold gas control knob down longer 
and harder.
2.  Determine  if  pilot  flame  extends  past  thermopile;  if  not, 
adjust pilot flame or clean pilot burner.
3.  Replace  thermopile  if  millivolt  reading  is  less  than  300 
millivolts when wall thermostat or remote bulb is turned OFF.   
Replace gas control if magnet dropout millivolt reading is 
over 100 millivolts.
Pilot Outage During Normal Operation
1.  Check input by manifold pressure gauge or gas meter.
2.  Check  millivolt  output  when  furnace  is  in  operation.    If 
millivolt  output  decreases  during  furnace  operation  gas 
control may be defective. 
Main Gas Valve Does Not Open When Thermostat Is Turned 
"On" 
1.  Check millivolt output of thermopile.
2.  Thermostat wires may be broken.
3.  Thermostat may be defective.
TROUBLESHOOTING