Index 
Part 
No. 
Number 
Description
  1 
GW-130 
Remote Bulb Control Kit
  2 
R-1224 
Remote Bulb Control
  3 
R-2499 
Wire Assembly
  4 
R-1162 
Control Knob
  5 
R-1720 
Plastic Clip (3 Required)
  6 
R-1223 
Instructions
  7 
R-1578 
No. 6-32 x 1/4" (6mm) Screw (2 Required)
Caution:    Remote  bulb  wire  routing  is  important.    Wires  should  be 
in proper location to avoid damage from being overheated.  
Incorrect  routing  of  remote  bulb  control  wires  may  result 
in damage to wires and incorrect  operation  of remote bulb 
control.  Follow these instructions and refer to the drawing for 
proper wire routing.
7.  If remote bulb control is located on the right side of the outer casing, 
carefully bend or loop capillary wire around control.  This will enable 
the sensing bulb to be positioned at the bottom of the unit.
8.  Secure sensing bulb on the inside, at the bottom, of the outer casing 
with (2) plastics clips.
9.  Feed the wire assembly down along the inside of the outer casing.
10.  Use third plastic clip to secure wire assembly and capillary wire to 
the casing.  (Approximately 24" (610mm) from bottom of unit.)
11.  Attach control knob to remote bulb control.
12.  Install furnace according to instructions in the Installation Instructions 
and Owner's Manual.
Note: If wall furnace is already installed, secure outer casing to unit.
13.  Attach wire assembly to gas valve at the "TH" and "TH/TP" terminals 
on the Robertshaw valve.
    Attach wire assembly to gas valve at the "THERMO" terminals on 
the ITT valve.  If the wire assembly has two 1/4" (6mm) female con-
nectors, the connectors should be cut off the wire assembly.  Strip 
and bare the wires and attach wires to the "THERMO" terminals. 
Note:  This remote bulb control is connected to the gas valve the same 
way as a wall thermostat. Any references made to the thermostat in the 
lighting instructions would also apply to the remote bulb control.
INSTRUCTIONS
Note:  At the option of the owner, the remote bulb  control may be located 
on the left  or right side of the outer casing.
1.  Remove remote bulb control from the shipping carton.
2.  Remove outer casing assembly from shipping carton.
Note: If wall furnace is already installed, remove outer casing from 
unit and lay on floor with front side down.
3.  Attach wire assembly to remote bulb control.
4.  Carefully unwind capillary wire on remote bulb control.
5.  Remove (3) hole plugs from left or right side of outer casing where 
remote bulb control is to be installed.
6.   Mount remote bulb control to inside of outer casing with (2) No. 6-32 
x 1/4" (6mm) screws. 
TO VENT SAFETY
TO REMOTE BULB
T
O
THER
MOPIL
E
MODELS
GWT-25 RB, GWT-35 RB, GWT-50 RB
REMOTE BULB CONTROL INSTALLATION INSTRUCTIONS