Important
  1.  The following service procedures are provided as a general 
guide.  
  2.  Meter readings between gas control and ignition module must 
be taken within the trial for ignition period.  Once the ignition 
module  locks  out,  the  system  must  be  reset  by  setting  the 
thermostat down for at least one minute before continuing.
  3.  If any component does not function properly,  make sure it is 
correctly installed and wired before replacing it.
  4.  The ignition module cannot be repaired.  If it malfunctions, it 
must be replaced.
  5.  Only trained, experienced service technicians should service 
intermittent pilot systems. 
Perform the 
CHECKOUT steps on page 10 as the first step in 
troubleshooting.  Then check TROUBLESHOOTING GUIDE 
to pinpoint the cause of the problem.  If troubleshooting indicates 
an ignition problem, see Ignition System Checks below to isolate 
and correct the problem.
Following troubleshooting, perform the CHECKOUT procedure 
(page 10 ) again to be sure system is operating normally.
Ignition System Checks
Step 1:  Check ignition cable.
Make sure:
  A.  Ignition cable does not touch any metal surfaces.
  B.  Ignition cable is no more than 36 inches (914mm) long.
  C.  Connections to the ignition module and to the  igniter-sensor 
are clean and tight.
  D.  Ignition cable provides good electrical continuity.
Step 2:   Check ignition system grounding.
 
Nuisance shutdowns are often caused by a poor or erratic 
ground.
  A.  A  common  ground,  usually  supplied  by  the  pilot  burner 
bracket, is required for the module and the pilot burner/igniter 
sensor.
•  Check for good metal-to-metal contact between the pilot 
burner bracket and the main burner.
•  Check the ground lead from GND (BURNER) terminal on 
the module to the pilot burner.  Make sure connections are 
clean and tight.  If the wire is damaged or deteriorated, replace 
it with No.  14-18 gauge, moisture-resistant, thermoplastic 
insulated wire with 105 C (221 F) minimum rating.
•  If flame rod or bracket are bent out of position, restore to 
correct position.
•  Replace  pilot  burner/igniter  sensor  if  insulator  is 
cracked.
Step 3:  Check spark ignition circuit.  You will need a short jumper 
wire made from ignition cable or other heavily insulated 
wire.
  A.  Close the manual gas valve.
  B.  Disconnect the ignition cable at the SPARK terminal on the 
module.
WARNING
When performing the following steps, do not touch stripped 
end of jumper or SPARK terminal.  The ignition circuit 
generates 13,000 volts at 25 pf load and electrical shock 
can result.
 
C. Energize the module and immediately touch one end of the jumper 
firmly to the GND terminal on the module.  Move the free end 
of the jumper slowly toward the SPARK terminal until a spark 
is established.
  D.  Pull the jumper slowly away from the terminal and note the 
length of the gap when sparking stops.  Check table below.
Step 4:  Check pilot flame current.
  A.  Turn off furnace at thermostat.
  B.  Disconnect main valve wire from the TH or MV terminal on 
the gas control.
  C.  Disconnect ground wire from GND (BURNER) terminal at 
module.
  D.  Connect a meter (dc microamp scale) in series with the ground 
lead.  
•  Disconnect  ground  lead  from  GND  terminal  on  ignition 
module.
•  Connect  the  black  (negative)  meter  lead  to  the  ignition 
module GND (BURNER) terminal.
•  Connect the red (positive) meter lead to the free end of the 
ground lead.
  E.  Set thermostat to call for heat.  The spark will light the pilot but 
the main burner will not light because the main valve actuator 
is disconnected.
  F.  Read the meter.  The flame sensor current must be steady and 
at least 1.0 uA.
  G.  If the reading is less than the minimum or unsteady,
•  Make sure pilot flame envelopes 3/8 (9.5mm)to 1/2 inch 
(13mm) of the flame rod.  
•  If  necessary,  adjust  pilot  flame  by  turning  the  pilot 
adjustment screw on the gas control clockwise to decrease 
or  counterclockwise  to  increase  pilot  flame.    Following 
adjustment,  always  replace  pilot  adjustment  cover  screw 
and tighten firmly to assure proper gas control operation.
•  Check for cracked ceramic insulator, which can cause short 
to ground, and replace igniter-sensor if necessary.
•  Make sure electrical connections are clean and tight.  Replace 
damaged wire with moisture-resistant No. 18 wire rated for 
continuous duty up to 105 C (221 F).
  H.  Remove  meter  and  reconnect  all  wires.    Return  system  to 
normal operation before leaving job.
ARC LENGTH
ACTION
No arc or arc less than 
1/8 inch (3mm).
Arc 1/8 inch (3mm) 
or longer.
Check external fuse, if provided.
Verify power at module input termi-
nal.
Replace module if fuse and power 
okay.
Voltage output is okay.
TROUBLESHOOTING