Introduction
Always  consult  your  local  Building  Department  regarding 
regulations, codes or ordinances which apply to the installation of 
a  vented wall furnace.
Instructions to Installer
1.  Installer  must  leave  instruction  manual  with  owner  after 
installation.
2.  Installer  must  have  owner  fill  out  and  mail  warranty  card 
supplied with furnace.
3.  Installer should show owner how to start and operate furnace 
and thermostat.
Warning:
Any change to this furnace or its control can be dangerous.  
This is a heating appliance and any panel, door or guard 
removed for servicing an appliance must be replaced prior 
to operating the appliance.
General Information
This series is design certified in accordance with American National 
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian 
Standards Association, as a Fan Type Vented Wall Furnace and 
must be installed according to these instructions.
Any alteration of the original design, installed other than as 
shown in these instructions or use with a type of gas not shown on 
the rating plate is the responsibility of the person and company 
making the change.
Important
All correspondence should refer to complete Model No., Serial 
No. and type of gas.
Notice:  During initial firing of this unit, its paint will bake out  and 
smoke will occur.  To prevent triggering of smoke alarms, ventilate 
the room in which the unit is installed.
Installation on Rugs and Tile
If  this  appliance  is  installed  directly  on  carpeting,  tile  or  other 
combustible material other than wood flooring the appliance shall 
be installed on a metal or wood panel extending the full width and 
depth of the appliance.  
The base referred to above does not mean the fire-proof base as 
used on wood stoves.  The protection is for rugs that are extremely 
thick and light colored tile.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed 
so that all burners and burner ignition devices are located not less 
than 18” (457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject 
to physical damage by a moving vehicle.  
Specifications
•  Due to high temperatures the appliance should be located 
out of traffic and away from furniture and draperies.
•  Children and adults should be alerted to the hazards of 
high surface temperatures and should stay away to avoid 
burns or clothing ignition.
•  Young children should be carefully supervised when they 
are in the same room as the appliance.
•  Clothing or other flammable material should not be placed 
on or near the appliance.
•  Any  safety  screen  or  guard  removed  for  servicing  an 
appliance  must  be  replaced  prior  to  operating  the 
appliance.
•  Keep burner and control compartment clean.  
•  Installation and repair should be done by a QUALIFIED 
SERVICE PERSON.   The appliance should be inspected 
before use and at least  annually  by  a qualified service 
person.  More frequent cleaning may be required due  to 
excessive lint from carpeting, bedding materials, etc.  It 
is imperative that control compartments, burners  and 
circulating  air  passageways  of  the  appliance  be  kept 
clean.
•  DO  NOT  put  anything  around  the  furnace  that  will 
obstruct the flow of combustion and ventilation air.
•  DO keep the appliance area clear and free from combustible 
material,  gasoline  and  other  flammable  vapors  and 
liquids.
•  DO  examine  venting  system  periodically  and  replace 
damaged parts.
•  DO make a periodic visual check of pilot and burners.  
Clean and replace damaged parts.
•  CAUTION: Pilot hole cover must be kept tightly closed 
during operation.
•  DO NOT use this heater if any part has been under water.  
Immediately call a qualified service technician to inspect 
the heater and to replace any part of the control system 
and any gas control which has been under water. 
•  This furnace must not be connected to a chimney flue 
serving a separate solid-fuel burning appliance.
THIS IS A HEATING APPLIANCE
DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANELS INSTALLED
.
INTRODUCTION
Model
FAW-55IP
BTU/HR (KW/H)
55,000 (16.1)
Height
82 3/8” (2092mm)
Width
16” (406mm)
Depth
11 1/2” (292mm)
Gas Inlet
1/2” (13mm) Pipe
Vent Collar
4” (102mm) Type B Oval
CFM
400
Accessories
See Page 16